BXXTK - P*L*U*S PIPE THREAD SEALANT, 51376

Product Identification

Product ID:P*L*U*S PIPE THREAD SEALANT, 51376
MSDS Date:07/07/1993
FSC:8030
NIIN:00N061133
MSDS Number: BXXTK

Responsible Party
FEL-PRO INC CHEMICAL PRODUCTS LP
7450 N MCCORMICK BLVD
SKOKIE, IL 60076-8205
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 303-289-5651

Preparer: CATHY GRIFFITH

Cage: JO068

Contractor
FEL-PRO INC DIV OF FELT PRODUCTS MFG CO
1103 SKOKIE, IL 60076-4046 US

Telephone: 847-674-7700 OR 312-761-4500

Cage: 73165

Ingredients

MICA - SILICATES (< 1% CRYSTALLINE SILICA); (SILICEOUS

CAS: 12001-26-2

RTECS: VV8760000

Fraction By Weight: 15%

OSHA PEL 20 MPPCF

ACGIH TLV: 3 MG/M3 RDUST


CASTOR OIL

CAS: 68187-84-8

Fraction By Weight: >3%

OSHA PEL N/K

ACGIH TLV: N/K


POLYETHYLENE; (POLYETHYLENE HOMOPOLYMERS)

CAS: 9002-88-4

RTECS: TQ3325000

Fraction By Weight: >3%

OSHA PEL N/K

ACGIH TLV: N/K


DRYING OILS; (DRYING OIL POLYMER)

Fraction By Weight: >3%

OSHA PEL N/K

ACGIH TLV: N/K


ETHYLENE, TETRAFLUORO-, POLYMER; (PTFE RESIN)

CAS: 116-14-3

RTECS: KX4025000

Fraction By Weight: >3%

OSHA PEL N/K

ACGIH TLV: N/K


TITANIUM OXIDE; (TITANIUM DIOXIDE)

CAS: 13463-67-7

RTECS: XR2275000

Fraction By Weight: >3%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 10 MG/M3 TDUST

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE:EYE:MECH IRRIT. CONT MAY CAUSE
TEARING & REDNESS. SKIN:NOT KNOWN TO BE AN IRRIT. INHAL:INHAL OF
DUST MAY CAUSE IRRIT. INGEST:MAY CAUSE NAUS & VOMIT. NO SPECIFIC
EFTS KNOWN. CHRONIC:THIS PROD CNT NS ENCAPSULATED MICA. RPTD &
PRLNGD OCCUP OVEREXP TO MICA MAY CAUSE DELAYED LUNG INJURY WHICH
MAY RSLT(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZS:IN PNEUMOCONIOSIS &/OR POS CHEST
X-RAYS. MICA CNTNS SM AMTS OF CRYSTALLINE SILICON DIOXIDE (QUARTZ)
WHICH HAS BEEN LISTED BY IARC & NTP AS SUSPECTED HUMAN CARCIN VIA
INHAL (MFR). NO EXPOS TO FREE RESP DUST IS ANTIC, HOWEVER, DURING
NORMAL APPLICATN OF THIS PROD. REFER TO RESP PROT FOR FURTHER REQS.
Medical Cond Aggravated by Exposure:PREEXISTING PULMONARY AND
DERMATOLOGICAL DISORDERS MAY BE AGGRAVATED BY EXPOSURE TO HAZARDOUS
COMPONENTS.

First Aid

First Aid:EYES:IMMEDIATELY FLUSH WITH PLENTY OF WATER FOR AT LEAST 15
MINUTES. OBTAIN MED ATTN. SKIN:FLUSH CONTAMINATED AREAS THOROUGHLY
WITH WATER. OBTAIN MED ATTN IF IRRITATION DEVELOPS. INHALATION:IF
EFFECTS OCCUR, REMOVE TO FRESH AIR. GIVE OXYGEN IF BREATHING IS
DIFFICULT. OBTAIN MED ATTN. INGESTION:DO NOT INDUCE VOMITING. GIVE
WATER/MILK IF VICTIM IS CONSCIOUS & NOT DROWSY. OBTAIN MED ATTN.

Fire Fighting

Flash Point:500F,260C
Extinguishing Media:CO*2, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP
USE WATER TO COOL EXPOSED CNTNRS. WATER STREAM DIRECTED INTO FIRE
MAY CAUSE FROTHING W/SUBSEQUENT (SUP DAT)
Unusual Fire/Explosion Hazard:CLSD CNTNRS MAY RUPTURE/EXPLODE (DUE TO
PRESS BUILD-UP) WHEN EXPOSED TO EXTREME HEAT. IRRIT &/OR TOX
GASES/FUMES MAY BE GENERATED BY THERMAL DECOMP/COMBUSTION.

Accidental Release

Spill Release Procedures:RECLAIM CLEAN MATERIAL. CONTAMINATED MATERIAL
SHOULD BE SWEPT OR SHOVELED INTO APPROPRIATE WASTE CONTAINER AND
DISPOSED OF IN ACCORDANCE WITH AP

Exposure Controls

Supplemental Safety and Health

Chemical Properties

Vapor Density:HVR/AIR
Spec Gravity:0.96
Evaporation Rate & Reference:SLOWER THAN BUTYL ACETATE
Solubility in Water:NEGLIGIBLE
Appearance and Odor:OFF-WHITE PASTE WITH NO APPRECIABLE ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG BASES OR OXIDANTS.
Stability Condition to Avoid:NO INFORMATION.
Hazardous Decomposition Products:ACRID FUMES. OXIDES OF CARBON.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.